Clip-On Coping
The panels are connected laterally by simply interlocking
into a groove, giving the elegant
appearance of either a recessed or hairline joint.
They are fixed onto extruded aluminium support
framework using mechanical fixings, which are concealed
in the inside edge on the groove.
| Features... |
| |
• |
All Aluminium
construction |
 |
• |
NO visible fixings |
| |
• |
Weather tight |
| |
• |
The chance of noise
is baffled out |
| |
• |
Thermal expansion
is
catered for 5 choices of exterior
finish |
| |
• |
Vast choice of
colours |
| |
• |
Minimum 25 year
finishing warranty |
| |
• |
Non-standard
profile designs catered for up to 4000mm long coping sections
available reducing joints. |
| BENEFITS
of using the Optima® Clip-On Coping |
 |
• |
Long life wall
protection |
| |
• |
Low maintenance |
| |
• |
Quick & Easy
Installation |
| |
• |
Individual units
can be quickly replaced |
| |
• |
All materials are
recyclable |
| |
• |
Supplied by a ISO
9002 quality assured company |
All Aluminium Construction?
Joint-straps and fixing clips are fabricated from robust
extruded, 6063 T6 grade aluminium. This extruded aluminium
support has a series of grooves into which the double EDPM
gaskets are fitted. The EDPM gasket acts as both the
weather protector, allowing water to drain off away from
the wall stopping any moisture from penetrating to the
brickwork, and as an anti-rattle device to baffle noise.
Design & Fabrication
Each project is different and although the coping design concept remains
the same, all coping and secret-fix support is manufactured to suit each
specific design requirement.
To enable design and fabrication to run smoothly, all technical drawings
and purchase data documents can be provided via email reducing the
overall fabrication time.
Fabricated units including stop-ends, corner units, junction tee-sections
and wall abutments shall be welded and dressed smooth in the visible
areas.
| Metal Finishing |
| Copings can be supplied
to site mill finished. Alternatively: - |
 |
• |
Polyester powder
coating is factory applied having undergone a
rigorous pre-treatment. The process is undertaken by quality
assured applicators to BS 6496. |
| |
• |
Anodising is factory
applied and also undergoes a rigorous pre-treatment. The
process is undertaken by quality assured applicators to
BS 1615 using the ANOLOK
process. |
| |
• |
Pre-finished aluminium
is available as stock items in metallic silver and white.
This material carries a BBA Agrément certificate
with a PVDF 70/30 finish applied. |
| |
• |
Post-coated aluminium
is also available to BS4842. |
All coatings are available in a wide range of colours and finishing warranties
up to 30 years are available subject to
the finishing type employed, colour and the physical and environmental location
of the building.
Details for fixing & allowing for Thermal Movement
Clips are fixed directly through to the wall structure at 1000mm centres with
M’12
screws. These provide the leveled line for the aluminium coping panel to be
clipped over. All fixings are concealed
leaving a clean, crisp coping line.
The co-efficient of the linear thermal expansion is 23 x 10-6 per degree centigrade
and a gap of 2 – 3mm between
each coping flashing section should be allowed. As the coping is not mechanical
fixed, it is free to expand and contract with changes in temperature has no
detrimental
effect on the wall
or the aesthetic appearance of the coping.
The Optima® Clip-on coping has a registered specification brief with National
Building Specification under clause H31

Product Specification Pack
To assist specifiers, Sotech has developed a New Product Specification Pack incorporating
product information, CAD details, and NBS Specification templates... (click
here to order).
Includes:
| • |
CAD drawings |
| • |
Typical NBS |
| • |
Product information |
|